Storm Trooper

Stormwater runoff from urban areas carries pollutants and trash into the storm drainage system. Unlike sanitary sewer systems, stormwater typically receives no treatment. Polluted stormwater eventually drains into public waterways, rivers, aquifers, lakes, and oceans. The pollutants can contain significant amounts of oils and sediment from impervious areas, which could be harmful to the environment, both biologically and aesthetically.
Although dramatic improvements have been made to the Nation’s water, degraded bodies of water still exist. Approximately 40% of surveyed American water bodies are still impaired by pollution and do not meet current water quality standards. A leading source of this impairment is polluted runoff.
Most storm water discharges are considered point sources and require coverage by an EPA NPDES permit. The primary method to control storm water discharge is through the use of Best Management Practices (BMP).
The Storm Trooper® Stormwater Interceptor is a practical Best Management Practice for treating Stormwater.
Impervious areas that are subject to stormwater runoff include roof tops, parking lots, streets, airport runways/taxiways, vehicle maintenance yards, wash down areas and yard areas of industrial and manufacturing facilities.
|
Storm Trooper System Sizing
|
| Cylindrical Style |
|
Rectangular Style |
|
Storm Trooper Model
|
Volume (Gal)
|
Treatment Capacity (>90% tss Removal)
|
Treatment Capacity (>85% tss Removal)
|
Treatment Capacity (>80% tss Removal)
|
|
Storm Trooper Model
|
Volume (Gal)
|
Treatment Capacity (>90% tss Removal)
|
Treatment Capacity (>85% tss Removal)
|
Treatment Capacity (>80% tss Removal)
|
| |
|
|
gpm
|
cfs
|
gpm
|
cfs
|
gpm
|
cfs
|
|
|
|
|
gpm
|
cfs
|
gpm
|
cfs
|
gpm
|
cfs
|
| SWST- |
5C
|
500
|
125
|
0.28
|
150
|
0.33
|
300
|
0.67
|
|
SWST- |
10
|
1000
|
300
|
0.67
|
335
|
0.75
|
650
|
1.45
|
|
SWST-
|
6C
|
600
|
175
|
0.39
|
200
|
0.45
|
400
|
0.89
|
|
SWST- |
15
|
1500
|
250
|
0.78
|
450
|
1.00
|
875
|
1.95
|
| SWST- |
8C
|
800
|
225
|
0.50
|
250
|
0.56
|
500
|
1.11
|
|
SWST- |
20
|
2000
|
400
|
0.89
|
575
|
1.28
|
1125
|
2.51
|
| SWST- |
10C
|
1000
|
300
|
0.67
|
335
|
0.75
|
650
|
1.45
|
|
SWST- |
25
|
2500
|
475
|
1.06
|
700
|
1.56
|
1375
|
3.06
|
| SWST- |
15C
|
1500
|
250
|
0.78
|
450
|
1.00
|
875
|
1.95
|
|
SWST- |
30
|
3000
|
550
|
1.22
|
800
|
1.78
|
1600
|
3.56
|
|
SWST-
|
20C
|
2000
|
400
|
0.89
|
575
|
1.28
|
1125
|
2.51
|
|
SWST-
|
35
|
3500
|
625
|
1.39
|
900
|
2.00
|
1775
|
3.95
|
| SWST- |
25C
|
2500
|
475
|
1.06
|
700
|
1.56
|
1375
|
3.06
|
|
SWST- |
40
|
4000
|
700
|
1.56
|
1000
|
2.23
|
1950
|
4.34
|
| SWST- |
30C
|
3000
|
550
|
1.22
|
800
|
1.78
|
1600
|
3.56
|
|
SWST-
|
50
|
5000
|
850
|
1.89
|
1225
|
2.73
|
2350
|
5.23
|
| SWST- |
35C
|
3500
|
625
|
1.39
|
900
|
2.00
|
1775
|
3.95
|
|
SWST- |
60
|
6000
|
1000
|
2.23
|
1400
|
3.12
|
2675
|
5.96
|
| SWST- |
40C
|
4000
|
700
|
1.56
|
1000
|
2.23
|
1950
|
4.34
|
|
SWST- |
70
|
7000
|
1150
|
2.56
|
1600
|
3.56
|
3000
|
6.68
|
| SWST- |
45C
|
4500
|
775
|
1.73
|
1100
|
2.45
|
2150
|
4.79
|
|
SWST- |
80
|
8000
|
1300
|
2.90
|
1775
|
3.95
|
3325
|
7.41
|
| SWST- |
50C
|
5000
|
850
|
1.89
|
1225
|
2.73
|
2350
|
5.23
|
|
SWST- |
90
|
9000
|
1450
|
3.23
|
1950
|
4.34
|
3675
|
8.07
|
| SWST- |
60C
|
6000
|
1000
|
2.23
|
1400
|
3.12
|
2675
|
5.96
|
|
SWST- |
100
|
10000
|
1600
|
3.56
|
2125
|
4.73
|
3900
|
8.69
|
|
|
|
|
|
|
|
|
|
|
SWST- |
110
|
11000
|
1750
|
3.90
|
2300
|
5.12
|
4175
|
9.30
|
|
|
|
|
|
|
|
|
|
|
SWST- |
120
|
12000
|
1900
|
4.23
|
2450
|
5.46
|
4425
|
9.86
|
|
|
|
|
|
|
|
|
|
|
SWST- |
130
|
13000
|
2050
|
4.57
|
2650
|
5.90
|
4725
|
10.52
|
|
|
|
|
|
|
|
|
|
|
SWST- |
140
|
14000
|
2200
|
4.90
|
2800
|
6.24
|
4950
|
11.02
|
|
|
|
|
|
|
|
|
|
|
SWST- |
150
|
15000
|
2350
|
5.23
|
2975
|
6.63
|
5200
|
11.58
|
|